| Compatibility | All GCT multi gas and single gas diffusion detectors |
|---|
| Size • Weight | 6.4" H x 2.6" W x 1.25" D (163 x 68 x 31 mm) • 8 oz. (235 g) |
|---|
| Battery life | 40 continuous hours (typically) |
|---|
| Charge time | 4 - 6 hours (typically) |
|---|
| Gas inlet | 1/8" stainless steel barbed fitting |
|---|
| Pump draw | Samples from up to 75 ft. (23 m) |
|---|
| Sample delay time | Less than 1 second per 1 ft. (0.3 m) with 1/8 in. ID tubing |
|---|
| Alarms | Visual & audible (minimum 95 dB) |
|---|
| LEDs | Pump Flow LED: the pump is on and/or blocked Power LED: the pump is on, and the battery life remaining Battery LED: the pump is charging, or fully charged |
|---|
| Tests | Full-function self-test upon activation Battery test runs continuously |
|---|
| Operating temperature | -7.6° to +122°F (-22° to +50°C) |
|---|
| Humidity | 5% to 100% RH (non-condensing) |
|---|
| Ratings | IP 68 |
|---|
| Certifications and approvals | Intrinsically safe CSA (CSA21CA80033769X): Class I, Division 1, Groups A, B, C and D, T4; Class I, Zone 0, AEx ia IIC T4 Ga IECEx (IECEx CSA 21.0006X): Ex ia IIC T4 Ga ATEX (CSANe 21ATEX2143X): II 1 G Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +50°C |
|---|
| Warranty | Full 2 years |
|---|
| Included | Charger, ten foot sampling hose, three foot connecting hose, stainless steel diffusion stone, ten additional filters (five hydrophobic & five particulate) and Quick Start Guide |
|---|