- 2 month battery life (continuous run time)
- 1 year calibration cycle
- Will work in inert environments, no need for oxygen
- Simple to use
- Bump/Calibration reminders
- Docking station compatible
- Programmable user ID
Day in, day out, your workers have to charge their portable multi gas detectors so they can keep testing for the presence of hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (LEL). Unfortunately, sometimes they may forget to do so. Gas Clip Technologies can help prevent this safety risk with the Multi Gas Clip (MGC).
The MGC can go a full 2 months without a charge, even without ever having to be turned off. Shut down the detector nightly and the battery can last up to 4 months.
What's the secret of the MGC's extended battery life? It uses low-power photo-metric technology for the detection of the combustible gases (LEL). Instead of draining the battery with archaic pellistor technology, the MGC uses an IR source. This conserves power, so the battery lasts and lasts and lasts.
The MGC also eliminates the need to frequently calibrate portable gas detectors. It can go 12 months without being calibrated. That saves time and increases efficiency.
| Gases | H2S: 0 - 100 ppm (0.1 ppm increments) CO: 0 - 500 ppm (1 ppm increments) Combustible (LEL): 0 - 100% LEL (0.1% increments) O2: 0 - 30% vol. (0.1% increments) |
|---|---|
| Sensor type | H2S, CO & O2: plug-in electrochemical cell Combustible (LEL): plug-in infrared |
| Size • Weight | 4.7" H x 2.4" W x 1.2" D (118.6 x 61.6 x 31.7 mm) • 7.7 oz. (240 g) |
| Battery life | 60 days (continuous) |
| Charge time | 4 - 6 hours |
| Recommended calibration frequency | 1 year |
| Alarms | Visual, vibrating & audible (minimum 95 dB) Low, High, STEL, TWA & OL (Over Limit) |
| LEDs | 4 red alarm bar LEDs Yellow back-light (activated on button press) Red back-light (activated on alarm condition) Yellow maintenance notification LED |
| Display | High viewing angle alphanumeric liquid crystal display (LCD) |
| Logs | 25 bump tests, 25 events, 25 calibrations Continuous 1-second data logging (typical capacity > 2 months) |
| Tests | Full-function self-test upon activation Sensors, battery and circuitry tests run continuously |
| Operating temperature | -4° to +122°F (-20° to +50°C) |
| Humidity | 5% to 95% RH (non-condensing) |
| Ratings | EMC Directive 2004/108/EC • IP 67 |
| Certifications and approvals | Intrinsically safe CSA (CSA13CA0014): Class I, Division 1, Groups A, B, C and D, T4; Ex ia IIC T4 Ga; Class I, Zone 0, AEx ia IIC T4 Ga IECEx (IECEx CSA 13.0014): Ex ia IIC Ga ATEX (SIRA 14ATEX2013): Ex ia IIC T4 Ga UKCA (CSAE 22UKEX1230): Ex ia IIC T4 Ga -20°C ≤ Ta ≤ +50°C |
| Warranty | Full 2 years |
| Included | Charger, calibration cap, calibration certification & Quick Start Guide |
| User options | Custom user message, TWA/STEL intervals, languages (6), latching alarms, self-test lock, auto-zero on start up, bump test interval, Low/High alarm, Off-Lock, TWA method, sensor enable/disable, maintenance notification, SAFE display, dock lock, calibration gas percentage, calibration interval, TWA/STEL alarm, % LEL or % CH4 by volume |
Source: MGC IR Datasheet v4.1. Specifications are subject to change without notice due to ongoing product development.