Multi Gas Clip Simple

Multi Gas Clip Simple

Part# MGC-S

MGC-Simple front view
MGC-Simple front view MGC-Simple left side view MGC-Simple side view MGC-Simple back view MGC-Simple back view

4 GAS DETECTOR with 2 YEAR RUN TIME

Gas Detection Made Simple

No charging ever! No calibration necessary! (Can be calibrated if required)

Reliably test for hydrogen sulfide (H2S), carbon monoxide (CO), oxygen (O2) and combustible gases (LEL) with this simple-to-use and simple-to-maintain detector. Just turn it on and have worry free assurance of protection against toxic gases 24/7 for two full years.

Low power usage is the key!

Gas Clip Technologies' continued refinement of advanced low-power photometric infrared technology for combustible gas measurement helps make gas detection simpler and safer than ever. The newest member of their gas detector family, the Multi Gas Clip Simple, features no charging ever and no calibrating necessary. It's SIMPLE to use!

Assembled in USA
Sold through distributors worldwide.
Features

  • 2 year run time - 2 year life!
  • 2 year warranty. For any service, please call our service center.
  • No charging ever! No calibration necessary!
  • Large, easy to read screen
  • Simple One Button Operation
  • Works in oxygen enriched and oxygen deficient environments
  • Continuous 1 second data logging
  • LEL sensor is immune to H2S & silicone poison
  • Assembled in USA
  • Compatible with MGC Simple Dock or MGC Simple Wall Mount Dock

Specifications
GasesH2S: 0 - 100 ppm (0.1 ppm increments)
CO: 0 - 500 ppm (1 ppm increments)
Combustible (LEL): 0 - 100% LEL (0.1% increments)
O2: 0 - 30% vol. (0.1% increments)
Sensor typeH2S, CO & O2: plug-in electrochemical cell
Combustible (LEL): soldered infrared (IR)
Size • Weight4.75" H x 2.75" W x 1.25" D (120.65 x 69.85 x 31.75 mm) • 7.675 oz. (220.2 g)
Battery life730 days continuous, no recharging (based on an average of 1 minute of alarm per day)
CalibrationRoutine calibration not necessary; can be calibrated
AlarmsVisual, vibrating & audible (minimum 95 dB)
Low, High, STEL, TWA & OL (Over Limit)
LEDs4 red alarm bar LEDs
Yellow back-light (activated on button press)
Red back-light (activated on alarm condition)
Yellow maintenance notification LED
DisplayHigh viewing angle alphanumeric liquid crystal display (LCD)
Logs50 bump tests, 50 events, 50 calibrations
Continuous 1-second data logging (typical capacity > 2 months)
TestsFull-function self-test upon activation
Sensors, battery and circuitry tests run continuously
Operating temperature-4° to +122°F (-20° to +50°C)
Humidity5% to 95% RH (non-condensing)
Ingress protectionIP 68
Certifications and approvalsIntrinsically safe
CSA (CSA16.70084100): Class I, Division 1, Groups A, B, C and D, T4; Ex ia IIC T4 Ga; Class I, Zone 0, AEx ia IIC T4 Ga
IECEx (IECEx CSA 16.0038): Ex ia IIC T4 Ga
ATEX (SIRA 16ATEX2288): Ex II 1G, Ex ia IIC T4 Ga
-20°C ≤ Ta ≤ +50°C
WarrantyFull 2 years
IncludedCalibration cap, calibration certificate & Quick Start Guide
User optionsCustom user message, TWA/STEL intervals, languages (6), latching alarms, self-test lock, bump test interval, Low/High alarm, maintenance notification, TWA method, sensor enable/disable, SAFE display, dock lock, calibration gas concentration, calibration interval, TWA/STEL alarm, % LEL or % CH4 by volume

Source: MGC Simple - MGC Simple Plus Datasheet v2.1. Specifications are subject to change without notice due to ongoing product development.

Data Sheets
Quick Start Guide
Manual
Software / Firmware
Videos
Accessories
External Pump
Detector(s) sold Separately.
External Pump
Part#: GCT-XP
The External Pump gives any Gas Clip diffusion detector the ability to take remote samples from up to 75 feet away, drawing air at greater than one foot per second, and comes with a two-year warranty.
GCT IR LinkGCT IR Link linked to MGC-SIMPLE detectorGCT IR LinkGCT IR Link linked to MGC-SIMPLE detector

*System Requirements: Microsoft Supported Windows Platforms

Detector(s) sold Separately.
GCT IR LINK communication module with USB cable
Part#: GCT-IR-LINK
GCT IR LINK communication module with USB cable (for use with all GCT detectors)

Pictured linked to an MGC-SIMPLE detector.
MGC Simple Dock
Detector(s) sold Separately.
MGC Simple Clip Dock
Part#: MGC-S-DOCK
Testing dock in portable with gas compartment, regulator, gauge, charger & USB memory (use with MGC Simple & Simple Plus)
MGC Simple Clip Dock Wall Mount
Detector(s) sold Separately.
MGC Simple
Wall Mount
Part#: MGC-S-WMDOCK
Testing dock in metal with gas compartment, regulator, gauge, charger & USB memory (use with MGC Simple & Simple Plus)
Hand Aspirator Kit
Detector(s) sold Separately.
Hand Aspirator Kit
Part#: GCT-HAK
Hand Aspirator Kit- Probe, Stone Filter, Sampling Hose, Bulb & Calibration Caps (use with Multi Gas Clip, MGC Simple & MGC Simple Plus)
Confined Space Kit
Detector(s) sold Separately.
Gas sold separately.
You can use any calibration gas cylinder as long as it has a C-10 connector.
Confined Space Kit
Part#: GCT-CSK
Hard sided carrying with foam insert, 1' sampling probe, air stone particulate filter, 10' sampling hose, hand aspirator pump, 3' calibration/test hose, calibration caps (Multi Gas Clip & MGC Simple/Simple Plus), 0.5lpm regulator and GCT IR LINK.
Confined Space Kit W/Gas
Detector(s) sold Separately.
You can use any calibration gas cylinder as long as it has a C-10 connector.
Confined Space Kit with 58L Quad Gas
Part#: GCT-CSK-GAS
Hard sided carrying with foam insert, 58L quad gas cylinder (25 ppm H2S, 100 ppm CO, 18% O2 & 50% LEL), 1' sampling probe, air stone particulate filter, 10' sampling hose, hand aspirator pump, 3' calibration/test hose, calibration caps (Multi Gas Clip & MGC Simple/Simple Plus), 0.5lpm regulator and GCT IR LINK.

Remote Sampling Probe - 1 ft.
Detector(s) sold Separately.
Remote Sampling Probe - 1ft.
Part#: PROBE-1
Remote Sampling Probe - 1 ft.
Manual Regulator
Detector(s) sold Separately.
Manual Regulator (non-dock use)
Part#: REG-MANUAL
Manual Regulator (non-dock use) use with all GCT detectors except MGC Pumps
Quad Gas Cylinder
You can use any calibration gas cylinder as long as it has a C-10 connector.
Quad Gas Cylinder
Part#: MGC-Q-60 / MGC-Q-120
Contains 25 ppm H2S,
100 ppm CO,
18% O2,
& 50% LEL (2.5% vol Methane.)
AVAILABLE in 60L or 120L
MGC Simple External Dust Filter Kit
Detector(s) sold Separately.
MGC Simple External Dust Filter Kit
Part#: MGC-S-X-FILTER-KIT
External Dust Filter Cap plus 5 filters (for use with MGC Simple * Simple Plus only)
Spares and Replacement Parts
Calibration Cap
Detector(s) sold Separately.
Calibration Cap
Part#: MGC-S-CALCAP
Calibration Cap replacement (for use with MGC-S & MGC-S-PLUS)
Alligator ClipAlligator Clip
Alligator Clip
Part#: AL-CLIP
Alligator Clip replacement (includes screw)
(For use with all GCT Detectors)
Calibration Hose 3 ft.
Calibration Hose 3 ft.
Part#: HOSE-3
Calibration Hose - 3 ft. Tygon ID-1/8" (3.18 mm), OD-1/4" (6.35 mm), Wall-1/16" (1.59 mm)
GCT IR Link USB Cable
GCT IR Link
USB Cable
Part#: GCT-IR-CABLE
GCT IR Link USB Cable
Dock Charger replacement
Dock not included.
Dock Charger replacement
Part#: DOCK-CHARGER
Dock charger replacement - std. 110v power supply (for all GCT Clip Docks)
Remote Sampling Probe Filter & Gasket Replacement Set
Detector(s) sold Separately.
Remote Sampling Probe
Filters & Gasket Replacement Set
Part#: PROBE-RF
Remote Sampling Probe Filter & Gasket Replacement Set
Remote Sampling Probe In-Line Water Trap Filter replacement
Detector(s) sold Separately.
Remote Sampling Probe In-Line Water Trap Filter replacement
Part#: MGC-WT
Remote Sampling Probe In-Line Water Trap Filter replacement
Sensor - H2S & CO Replacement
Detector(s) sold Separately.
Sensor - H2S & CO Replacement
Part#: MGC-SE-4DT
MGC H2S & CO replacement (Dual-Tox) for all MGCs & MGC Pumps
Replacement Filters (Qty 2)
Detector(s) sold Separately.
Replacement Filters (Qty 2)
Part#: MGC-S-FILTER-2
MGC-Simple Filter: Complete Filter Replacement Kit (2 Pack)
Replacement Filters (Qty 10)
Detector(s) sold Separately.
Replacement Filters (Qty 10)
Part#: MGC-S-FILTER-10
MGC-Simple Filter: Complete Filter Replacement Kit(10-Pack)